> For the complete documentation index, see [llms.txt](https://docs.moasure.com/en/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.moasure.com/en/moasure-one-and-moasure-2-series/your-moasure-device/moasure-one-and-moasure-2-series-accuracy.md).

# Moasure ONE and Moasure 2 Series Accuracy

Compare measurement accuracy for Moasure ONE, Moasure 2 and Moasure 2 PRO, see what the figures mean in practice, and learn how to improve your results.

### How Moasure Measures

Moasure ONE, Moasure 2 and Moasure 2 PRO use motion sensors to track changes in position as you move between pause points. At each pause point, set the device down and keep it completely still until the app captures a measurement point.

The app records each point’s position and elevation relative to the start of the measurement. It uses those points to calculate distance, perimeter, area and volume.

***

### How Time Between Pauses Affects Accuracy

**Error increases with time, not distance.** The longer your Moasure stays in motion between pause points, the more error can build up.

Walk at a steady, confident pace. If a stretch would take around 10 seconds to walk, add a pause point partway along so you can cover it in two shorter movements.

Use the timer bar and audio cues to judge when to pause. Aim to set the device down while the bar is still green. If it turns amber, place the device before it turns red.

For more guidance, see [Master Pace](https://docs.moasure.com/en/moasure-one-and-moasure-2-series/your-moasure-device/measuring-technique/master-pace) and [Measuring Time / Accuracy](https://docs.moasure.com/en/moasure-one-and-moasure-2-series/your-moasure-device/measuring-time-accuracy).

{% hint style="info" %}
**Moasure 2 PRO only:** You can adjust the measuring time in the app by choosing between Highest Accuracy (6–8 seconds) and Longest Time (12–16 seconds). For the highest accuracy, we recommend pausing every 6–8 seconds.
{% endhint %}

### Accuracy by Device

The table shows the published accuracy for a single measurement. The **±** symbol indicates how far the result may vary above or below the actual value. Accuracy varies with device handling and measuring technique.

<table data-header-hidden data-search="false"><thead><tr><th></th><th></th><th></th><th></th><th></th></tr></thead><tbody><tr><td><strong>Measurement type</strong></td><td><strong>Description</strong></td><td><strong>Moasure 2 PRO</strong></td><td><strong>Moasure 2</strong></td><td><strong>Moasure ONE</strong></td></tr><tr><td>Linear distance</td><td>Straight-line distance between two points</td><td>±0.3%</td><td>±0.5%</td><td>±0.5%</td></tr><tr><td>Perimeter</td><td>Distance around a shape</td><td>±0.5%</td><td>±1%</td><td>±1%</td></tr><tr><td>Elevation</td><td>Change in height</td><td>±0.3%</td><td>±0.5%</td><td>±0.5%</td></tr><tr><td>Area</td><td>Area enclosed by a shape</td><td>±1%</td><td>±2%</td><td>±2%</td></tr><tr><td>Volume</td><td>Volume of cut, fill or stockpiles</td><td>±1.5%</td><td>±3%</td><td>±3%</td></tr><tr><td>Layout</td><td>Marking out points from a plan</td><td>±1%</td><td>Not available</td><td>Not available</td></tr></tbody></table>

To see how these figures apply to different measurements, use the [interactive accuracy calculator](https://www.moasure.com/pages/accuracy#moasure-2-series).

***

### What the Accuracy Figures Mean in Practice

For a **100 m linear distance**, the published accuracy is **±0.3 m** with Moasure 2 PRO and **±0.5 m** with Moasure 2 or Moasure ONE. The examples below show how the published percentages translate into metric and imperial units for **Moasure 2 PRO**.

#### Metric Examples

<table data-header-hidden data-search="false"><thead><tr><th></th><th></th><th></th></tr></thead><tbody><tr><td><strong>Measurement type</strong></td><td><strong>Example measurement</strong></td><td><strong>Published tolerance</strong></td></tr><tr><td>Linear distance</td><td>100 m</td><td>±0.3 m</td></tr><tr><td>Perimeter</td><td>100 m</td><td>±0.5 m</td></tr><tr><td>Elevation</td><td>100 m</td><td>±0.3 m</td></tr><tr><td>Area</td><td>100 m²</td><td>±1 m²</td></tr><tr><td>Volume</td><td>100 m³</td><td>±1.5 m³</td></tr><tr><td>Layout</td><td>100 m</td><td>±1 m</td></tr></tbody></table>

#### Imperial Examples

<table data-header-hidden data-search="false"><thead><tr><th></th><th></th><th></th></tr></thead><tbody><tr><td><strong>Measurement type</strong></td><td><strong>Example measurement</strong></td><td><strong>Published tolerance</strong></td></tr><tr><td>Linear distance</td><td>300 ft</td><td>±0.9 ft</td></tr><tr><td>Perimeter</td><td>300 ft</td><td>±1.5 ft</td></tr><tr><td>Elevation</td><td>300 ft</td><td>±0.9 ft</td></tr><tr><td>Area</td><td>300 ft²</td><td>±3 ft²</td></tr><tr><td>Volume</td><td>300 ft³</td><td>±4.5 ft³ (about ±0.167 yd³)</td></tr><tr><td>Layout</td><td>300 ft</td><td>±3 ft</td></tr></tbody></table>

### How to Improve Accuracy

* [**Pace**](https://docs.moasure.com/en/moasure-one-and-moasure-2-series/your-moasure-device/measuring-technique/master-pace.md)**:** Walk at a steady, natural pace between pause points. Use the timer bar or audio cues to know when to pause.
* [**Placement**](https://docs.moasure.com/en/moasure-one-and-moasure-2-series/your-moasure-device/measuring-technique/master-placement.md)**:** Set the device down promptly and gently, then keep it completely still until the app captures the point. On grass or uneven ground, gently press down on Moasure STICK to keep the device steady.
* [**Rotation**](https://docs.moasure.com/en/moasure-one-and-moasure-2-series/your-moasure-device/measuring-technique/master-rotation.md)**:** When the reference point needs to face a different direction, rotate the device gradually as you move between pause points. Complete the turn before setting the device down.

Watch the tutorial on [Measuring Technique](https://docs.moasure.com/en/moasure-one-and-moasure-2-series/your-moasure-device/measuring-technique) for further guidance on pace, placement and rotation.

***

### Check Your Start/Finish Error

When you finish a closed shape, review the **Start/Finish error** in the app. It indicates how closely the end of the measurement matches the start. Aim for **under 1%** where possible.

If the Start/Finish error is higher than expected, use [Moasure Coach](https://docs.moasure.com/en/moasure-one-and-moasure-2-series/your-moasure-device/measuring-technique/use-moasure-coach) to review any points flagged for technique. Use the feedback to adjust your pace, placement or rotation, then repeat the measurement and check the result.

Moasure Coach highlights specific parts of your measurement and provides guidance on:

* Where accuracy dropped
* What caused it (e.g. movement, placement, timing)
* How to correct it in your next measurement

Improve your technique and remeasure for better results.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.moasure.com/en/moasure-one-and-moasure-2-series/your-moasure-device/moasure-one-and-moasure-2-series-accuracy.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
